Product Code: 2-7000039In Stock

Neurotrac Sports XL

$265.00

Four Channel Digital Muscle Stimulator

Four Channel Digital Muscle Stimulator

SKU: 2-7000039 Categories: ,
2 channel NMS stimulator, works like 4 channel (each channel is forked into two pairs of electrodes) Model number: ETS201 - we don't sell to the general public, please obtain the unit from your local distributor   21 preset Sports Programs. Advanced multi-phase programs where treatment is split into time phases with different stimulation parameters   STIM
    • Dual channel: individually isolated circuits.
    • Amplitude: 0-90 mA into 500 Ohm load; indication only. Actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 86 mA, at 1500 Ohms load the maximum will be limited to 65 mA.
    • Type: Constant Current, maximum output voltage 180 Volts 10 / -30 Volts
    • Waveform: Symmetrical, rectangular bi-phasic with zero DC current.
    • Selectable pulse width: 50 ?S 330 ?S [2% accuracy].
    • Pulse Rate selection: in the continuous mode 2 100 Hz [2% accuracy].
    • Time duration of the treatment selectable: 1 minute to 90 minutes.
    • Low Battery Indicator: If the battery goes below 6.9 volts /- 0.2 volts the battery symbol will flash on/off once every second.
    • Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.
    • Ramp up time 0.1 - 9.9 seconds.
    • If the battery voltage is below 6.6 ( /- 0.2) volts the unit will not turn on.
  Physical dimensions: 134 x 69 x 29.7 mm. Weight: 0.18 KG with battery. Environmental Conditions for use: 10 to 30 degrees Centigrade. 0-90% Humidity. Environmental conditions for storage & transport: -10 to 50 degrees Centigrade. 0-90% Humidity.
  • Programme : P01 Warm up
  • Programme : P02 Capillary
  • Programme : P03 Endurance
  • Programme : P04 Resistance force output 1
  • Programme : P05 Resistance force output 2
  • Programme : P06 Resistance force output 3
  • Programme : P07 Maximum force output
  • Programme : P08 Explosive force output
  • Programme : P09 Lipocytes Metabolism 1
  • Programme : P11 Muscle at Rest
  • Programme : P12 Mass Muscle Contraction
  • Programme : P13 Active Recovery
  • Programme : P14 Muscle Toning
  • Programme : P15 Calming the Muscle
  • Programme : P16 Pain Relief
  • Programme : P17 Lipocytes Metabolism 2
  • Programme : P18 Explosive Strength Level 1
  • Programme : P19 Explosive Strength Level 2
  • Programme : P20 Explosive Strength Level 3
  • Programme : P21 Explosive Strength Level 4
MF = MODULATED FREQUENCY IN LINEAR STEPS W/R = INTERMITTENT WORK/REST CONT = CONTINUOUS MODULATION TIME = EXPONENTIALLY Example: Modulation time 10 seconds 150?S-250?S:- means starting at 150μS increasing exponentially (fast then slow) to 250μS in five seconds and returning (fast then slow) back to 150μS to complete the cycle in 10 seconds.